Duty Cycle

When the load is intermittent and the duty cycle is much shorter than the transformer’s thermal time constant (which is several hours), a smaller transformer can be used.  

 

Regulation and Temperature Rise-Power-Tronix

Voltage Regulation

The toroidal transformer’s output voltage increases slightly at partial load. The voltage drop can be reduced and the regulation improved by using larger diameter wire or a larger core.

 

 

Regulation and Temperature Rise-Power-TronixTemperature Rise

 

POWERTRONIX transformers are designed for a temperature rise at full load of 60 degrees Celsius above ambient temperature. At lower output power, the temperature rise is significantly less.

If required, we can provide the toroidal transformer with a thermal protector to automatically turn off the transformer at a set temperature.